The DP Alarm Slave Unit provides a clear, remote indication of a vessel’s Dynamic Positioning system status for personnel working away from the bridge. Designed for commercial diving and offshore operations, the unit receives electrical signals from the associated DP Alarm Master Unit and displays the corresponding vessel DP condition using high-visibility status LEDs and an audible alarm.
The unit provides three clearly defined DP status indications:
- Green, NORMAL
- Orange, DEGRADED
- Red, EMERGENCY
When the vessel’s DP status changes to DEGRADED or EMERGENCY, the appropriate warning LED illuminates and the audible alarm sounds. An Alarm Accept switch allows the operator to mute the audible alarm while the relevant status LED remains illuminated. The indicated status can only be changed from the Master Unit, helping ensure that personnel at the remote station remain aware of the vessel’s current DP condition.
The DP Alarm Slave Unit is particularly suited to commercial diving operations where dive supervisors, diving personnel or other operational teams require immediate notification of changes to the vessel’s DP condition.
Key Features
- Remote indication of vessel Dynamic Positioning status
- Three DP status indicators:
- Green, NORMAL
- Orange, DEGRADED
- Red, EMERGENCY
- Audible warning alarm
- Alarm acknowledgement and mute function
- Warning LED remains illuminated after alarm acknowledgement
- Status controlled from the associated DP Alarm Master Unit
- Simple operator interface
- Rack-mounted 2U enclosure
- Rear interface cable glands
- Suitable for commercial diving and offshore applications
- Designed for installation at a remote operating location away from the vessel bridge
How the DP Alarm Slave Unit Works
The DP Alarm Slave Unit operates as a remote repeater for the vessel’s DP alarm system.
The connected Master Unit sends an electrical signal corresponding to the current Dynamic Positioning status. The Slave Unit then provides both visual and audible notification to personnel at the remote operating station.
During normal operation, the green NORMAL LED is illuminated.
If the vessel DP condition changes to DEGRADED, the orange warning LED illuminates and the audible alarm sounds.
If the vessel DP condition changes to EMERGENCY, the red warning LED illuminates and the audible alarm sounds.
The operator can acknowledge either alarm using the front-mounted Accept switch. This silences the audible warning while maintaining the visual indication until the status is changed at the Master Unit.
Typical Applications
The DP Alarm Slave Unit is suitable for:
- Commercial diving vessels
- Dynamic Positioning vessels
- Dive control rooms
- Saturation diving systems
- Offshore construction vessels
- DSV operations
- Subsea intervention projects
- Offshore inspection and maintenance
- Remote operational control stations
- Areas where personnel require immediate indication of DP status
Technical Specification
| Specification | Details |
|---|---|
| Product | DP Alarm Slave Unit |
| Function | Remote DP status indication |
| Status Indication | NORMAL, DEGRADED, EMERGENCY |
| Normal Indicator | Green LED |
| Degraded Indicator | Orange LED |
| Emergency Indicator | Red LED |
| Audible Alarm | Integrated |
| Alarm Acknowledge | Front-mounted Accept switch |
| Power Supply | 12 / 24 VDC |
| Protection | IP66, front fascia only |
| Operating Temperature | -40°C to +70°C |
| Enclosure | 2U rack mount |
| Depth | 364 mm |
| Connections | Rear interface glands |
The manufacturer’s manual specifies a 2U rack enclosure with rear glands and identifies the front-panel controls as the NORMAL, DEGRADED and EMERGENCY status LEDs, alarm and alarm acceptance switch.
Maintenance and Certification
The DP Alarm Slave Unit should be regularly inspected in accordance with applicable company and operational procedures.
The manufacturer’s documentation recommends periodic mechanical inspection and states that component replacement should only be undertaken by qualified personnel, followed by appropriate system testing.
The manual also references visual and function testing at six-month intervals and identifies the equipment under IMCA D018 electrical equipment testing.
DP Alarm Systems for Commercial Diving Operations
A DP alarm system provides an important communication link between the vessel’s Dynamic Positioning status and personnel involved in diving operations.
By installing a DP Alarm Slave Unit within the dive control room or another remote operational area, dive supervisors can receive immediate visual and audible notification when the vessel’s DP status changes, allowing the appropriate operational procedures to be implemented.
Enquire About the DP Alarm Slave Unit
For technical details, pricing, system configuration or assistance specifying a complete Dynamic Positioning Alarm System, contact the iSubC team.